Use of the implement
UX01 Super CP Plus BAG0229.2 11.21
173
11.3.4 Residual amounts
There are three types of residue:
•
Excess residue remaining in the spray liquid tank when the
spraying operation is finished.
→
This excessive residue is discharged diluted or pumped-out and
disposed of.
•
Technical residue that remains in the spray liquid tank, the
suction valve chest and the spray line when the spray pressure
drops by 25%.
The suction chest is composed of the suction filter, pump and
pressure controller sub-assemblies. Observe the values for the
technical residues given on page 104.
→
This technical residue is discharged diluted onto the field while
cleaning the field sprayer.
•
Final residue that remains in the spray liquid tank, the suction
valve chest and the spray line after being cleaned and air is
discharged from the nozzles.
→
This final diluted residue is drained off after cleaning.
Disposing of the residues
•
Make sure that the residue in the spray line continues to be
sprayed in an undiluted concentration. Always spray this residue
on an untreated area. The distance needed to use up this
undiluted residue can be found in the section "Technical Data -
spray lines", page 104. The residue contained in the spray line is
dependent on the sprayer boom working width.
•
To spray out the spray liquid tank until it is empty, switch off the
agitator when the residue in the spray liquid tank is only 5% of
the nominal volume. When the agitator is switched on, the
technical residue is higher than the specified values.
•
Measures intended for the user's protection apply when
emptying residues. With the agitator switched on, the technical
residue increases in comparison to the specified values.
Formula for calculating the required distance in [m] for spraying
out the undiluted residue in the spray line:
Required distance [m] =
Undilutable residue [l] x 10,000 [m2/ha]
Application rate [l/ha] x working width [m]
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...