Quick cleaning of the empty field sprayer
1. Run the pump.
Control terminal, Cleaning menu:
QUICK CLEANING
The following conditions must be fulfilled:
2. The conditions must be fulfilled. Compare
the setpoints and actual values.
3.
>
Start the quick cleaning.
200 litres of flushing water are required
→
Main and secondary agitator are flushed,
tank internal cleaning switched on.
Implements with DUS: the spray line is
cleaned.
4.
>
Confirm and start driving at the same
time.
→
Cleaning water is sprayed out.
Spraying is switched on and off several
times.
AmaSelect: The nozzle body is completely
flushed.
If necessary, also switch the boundary
nozzles.
5.
>
Residue will be drained.
x
Do not drain residue (residue will be
drained and collected later).
6. TwinTerminal: Clean the suction filter and
pressure filter, see section on cleaning the
suction filter / pressure filter.
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......