Cleaning the implement after operation
UX01 Super CP Plus BAG0229.2 11.21
183
Cleaning the pressure filter when the spray liquid tank is full
HighFlow: Do not clean the separate
HighFlow pressure filter when the spray
liquid tank is full.
1. TwinTerminal:
Start the pressure
filter cleaning.
2. The spraying pump may not be driven!
WARNING
Unwanted emptying of the spray
liquid tank via quick emptying!
Never run the pump.
Single nozzle control:
Close the return flow stop tap on the
sprayer boom (Position 0).
3.
Confirm.
4. Place a collecting bucket under the outlet.
5.
Confirm.
6. Wait until the pressure filter is drained (5
seconds).
7.
Confirm.
8. Remove the pressure filter, clean and
reinstall.
9.
Confirm.
10. TwinTerminal:
Stop the pressure
filter cleaning.
→
→
→
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......