Faults
186
UX01 Super CP Plus BAG0229.2 11.21
Malfunction
Cause
Remedy
AmaSelect: Nozzles do not
close completely
Limescale in the nozzle body
Eliminate limescale in the
system, refer to the Maintenance
section
There is no suction from the
pump
Blockage on the suction side
(suction filter, filter insert, suction
hose).
Remove the blockage.
Pump is sucking in air.
Check the hose connection of the
suction hose (optional) on the
suction port for leak tightness.
The pump does not have any
power
Suction filter and filter insert dirty. Clean suction filter and filter
insert.
The valves are jammed or
damaged.
Change the valves.
The pump draws air, can be seen
by air bubbles in the spray liquid
tank.
Check the hose connections on
the suction hose for leak
tightness.
The spray cone vibrates
Irregular delivery flow from the
pump.
Check, and if necessary replace,
the suction and pressure-side
valves (see Seite 221).
Oil/spray liquid mixture in the
oil filler neck or clearly visible
oil consumption
Pump diaphragm defective.
Change all six piston diaphragms
(see 222).
The required application rate
entered is not achieved
High forward speed; low pump
drive speed;
Reduce the operational speed
and increase the pump drive
speed until the fault message
disappears and the audible alarm
signal stops
There has been a deviation
from the permissible spray
pressure range for the nozzle
fitted to the sprayer boom
Deviation from the prescribed
operational speed, which has an
effect on the spray pressure
Alter your operational speed to
return to the prescribed
operational speed range set for
spraying operation
Failure of the sprayer boom
Flex-folding
Wiring harness is defective
Fold the boom manually, see
page 219, contact a specialist
workshop.
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......