Cleaning the implement after operation
UX01 Super CP Plus BAG0229.2 11.21
181
12.5
Performing chemical cleaning
•
Chemical cleaning is recommended before critical agent
changes and before the implement is decommissioned for a
longer period of time.
•
Perform the chemical cleaning after the intensive cleaning.
1. Clean the implement.
2. Fill the spray liquid tank with 100 l of water
and add the cleaning agent according to the
instructions provided by the manufacturer.
To flush in the cleaning agent, the spray
liquid tank must be filled with at least 200 l of
water.
3. Run the pump.
4. TwinTerminal:
Switch on the
circulation cleaning (at least 10 minutes,
observe the instructions from the cleaning
agent manufacturer).
5. Control terminal: Select the agitator and
operate at maximum intensity for one
minute.
6. TwinTerminal:
Stop the circulation
cleaning.
7. Spray out the mixture on the previously
treated field.
List of available cleaning agents
Product
Manufacturer
Agro-Quick
Adama
JET CLEAR
Sudau agro
Proagro Spritzenreiniger
proagro GmbH
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......