Cleaning, maintenance and repairs
UX01 Super CP Plus BAG0229.2 11.21
227
Example:
Noz. size
'06'
Intended forward speed
7 km/h
Nozzle output on the left boom section: 0.85 l/30s
Nozzle output in the middle
0.84 l/30s
Nozzle output on the right boom section: 0.86 l/30s
Calculated average value:
0.85 l/30s
→
1.7 l/min
1. Determining the individual nozzle output [l/ha] with the quick-
check cup
(1)
→
Determined application rate 290 l/ha
(2)
→
Determined spray pressure 1.6 bar
2. Calculating the individual nozzle output [l/ha]
d [l/min] x 1200
=
Application rate
[l/ha]
e [km/h]
ο
d: Nozzle output (calculated average value) [l/min]
ο
e: Forward speed [km/h]
1.7 [l/min] x 1200
= 291 [l/ha]
7 [km/h]
3. Reading the individual nozzle output [l/ha] from the spray table
From the spray table (see page 247):
→
Application rate 291 l/ha
→
Spray pressure 1.6 bar
If the determined values for the application rate and application
pressure do not match the set values:
•
Calibrate the flow meter (see control terminal ISOBUS operating
manual)
•
Check all nozzles for wear and blockages.
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......