![Amazone UX 4201 Super Скачать руководство пользователя страница 232](http://html1.mh-extra.com/html/amazone/ux-4201-super/ux-4201-super_operating-manual_2919782232.webp)
Cleaning, maintenance and repairs
232
UX01 Super CP Plus BAG0229.2 11.21
Pressure gauge test
and boom part width section chest
1. Remove one spray line from a part-width
section valve and seal it with the blind hose
(order no. 1166060).
2. Connect the pressure gauge connection to
a part width section valve with the help of
the turned socket.
3. Screw the check gauge 1/4 of an inch into
the inside thread.
4. Switch on spraying
DUS pro single nozzle control
1. Disconnect the return line (1) beside the
pressure sensor and seal it with the blind
hose (order no. 1166060).
2. Connect the pressure gauge connection
(order no. 7107000) to the spray line (2).
3. Screw the check gauge 1/4 of an inch into
the inside thread.
4. Switch on spraying.
Содержание UX 4201 Super
Страница 21: ...General safety instructions UX01 Super CP Plus BAG0229 2 11 21 21...
Страница 236: ...Diagrams and overviews 236 UX01 Super CP Plus BAG0229 2 11 21 15 1 Liquid circuit Part width section control...
Страница 238: ...Diagrams and overviews 238 UX01 Super CP Plus BAG0229 2 11 21 15 3 Liquid circuit Part width section control AmaSwitch...
Страница 239: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 239 15 4 Actuators and sensors...
Страница 240: ...Diagrams and overviews 240 UX01 Super CP Plus BAG0229 2 11 21 15 5 Hydraulic diagram Basic implement...
Страница 241: ...Diagrams and overviews UX01 Super CP Plus BAG0229 2 11 21 241 Profi folding ContourControl and SwingStop...
Страница 247: ...UX01 Super CP Plus BAG0229 2 11 21 247...
Страница 256: ......