![Amazone Precea 4500-2 Скачать руководство пользователя страница 187](http://html1.mh-extra.com/html/amazone/precea-4500-2/precea-4500-2_original-operating-manual_2919774187.webp)
10-amp fuse
Protected rows
F1
Row 1 to 4
F2
Row 5 to 8
F3
Row 8 to 12
1.
Clean the singling unit.
2.
Check the singling disc for ease of movement.
3.
Replace defective fuses.
1.
Remove the defective shear pin
2
.
2.
Remove the defective shear pin from the drive
shaft
3
.
3.
Clean the singling unit.
4.
Check the singling disc for ease of movement.
5.
Install the new shear pin
1
.
CMS-I-00002696
Fill level in the singling unit housing is too high
The scraper removes excess seed from the singling
disc. If the brushes of the filling block are worn, the
seed does not flow back into the storage area
2
within the filling block.
To replace the defective filling block,
see "Changing the singling disc"
or
contact your specialist workshop.
CMS-I-00005635
CMS-T-00008170-A.1
8 | Eliminating faults
MG6149-EN-GB | J.1 | 18.10.2022 | © AMAZONE
181