![Amazone Precea 4500-2 Скачать руководство пользователя страница 141](http://html1.mh-extra.com/html/amazone/precea-4500-2/precea-4500-2_original-operating-manual_2919774141.webp)
The sliding shutter is completely open
1
The sliding shutter is opened to 1/3
2
The sliding shutter is closed
3
CMS-I-00002689
4.
If the setting range is between 0.1 and 5,
move the sliding shutter for the fertiliser metering
unit to position
2
.
The supply to the metering unit is reduced.
5.
Repeat the calibration.
6.5.18 Changing the application rate for liquid fertiliser
The liquid fertiliser metering unit
1
is connected to
the tank via the supply hose
3
. The liquid fertiliser
flows through the hose
2
to the application point
and is applied in the soil.
CMS-I-00002729
A = Rate in l/ha
A
R
= Pure fertiliser rate in kg/ha
G
%
= Fertiliser content in percent
ϱ = Density in kg/l
1.
Determine the application rate for the fertiliser
using the equation.
A
A
G
A
28
A
R
%
=
´
´
=
´
´
=
=
´
´
=
100
55 100
1 28
153 5
100
r
,
,
CMS-I-00002734
CMS-T-00003722-C.1
6 | Preparing the machine
Preparing the implement for operation
MG6149-EN-GB | J.1 | 18.10.2022 | © AMAZONE
135