69
HT 6Split
HT 12Split
Performance
Outdoor module / HT 6Split / HT 12Split
L6Split /
HT 6Split
L8Split /
HT 12Split
L12Split /
HT 12Split
Heating
Outd. temp. /
Supply temp.
Nominal
Nominal
Nominal
Output data according to EN14511
ΔT5K
Specified/supplied power/COP (kW/
kW/-)
7/35°C (floor)
2,67/0,5/5,32
3,86/0,83/4,65
5,21/1,09/4,78
2/35°C (floor)
2,32/0,55/4,2
5,11/1,36/3,76
6,91/1,79/3,86
7/45°C
2,28/0,63/3,62
3,70/1,00/3,70
5,00/1,31/3,82
2/45°C
1,93/0,67/2,88
5,03/1,70/2,96
6,80/2,24/3,04
Cooling
Outd. temp. /
Supply temp.
Max.
Max.
Max.
Output data according to EN14511 ΔT5K
Specified/supplied power/EER
27/7°C
5,87/1,65/3,56
7,52/2,37/3,17
9,87/3,16/3,13
27/18°C
7,98/1,77/4,52
11,20/3,20/3,50
11,70/3,32/3,52
35/7°C
4,86/1,86/2,61
7,10/2,65/2,68
9,45/3,41/2,77
35/18°C
7,03/2,03/3,45
9,19/2,98/3,08
11,20/3,58/3,12
Max. operating current and recommended fuse
rating when connected 3x400 V
Unit
HT 6Split
+ L6Split
HT 12Split
+ L8Split
HT 12Split
+ L12Split
Max. operating current compressor
A
16
16
20
Max operating current heat pump including 3 kW
immersion heater, compressor working and enabled
contactor K1 (Recommended fuse rating)
A
16 (20)
16 (20)
20 (20)
Max operating current heat pump including 6 kW
immersion heater, compressor working and enabled
contactor K1+K2 (Recommended fuse rating)
A
16 (20)
16 (20)
20 (20)
Max operating current heat pump including 9 kW
immersion heater, compressor working and enabled
contactor K1+K2 +K3 (Recommended fuse rating)
A
20 (20)
20 (20)
20 (20)
Max operating current 9 kW immersion heater, com-
pressor not working and enabled contactor K1+K2
+K3 (Recommended fuse rating)
A
20 (20)
20 (20)
20 (20)
Chapter 13 |
Technical data
Max. operating current and recommended fuse
rating when connected 1x230 V
Unit
HT 6Split
+ L6Split
HT 12Split
+ L8Split
HT 12Split
+ L12Split
Max. operating current compressor
A
16
16
20
Max operating current heat pump including 1,5 kW
immersion heater, compressor working and enabled
contactor K1 (Recommended fuse rating)
A
22,5 (25)
22,5 (25)
26,5 (25)
Max operating current heat pump including 3 kW
immersion heater, compressor working and enabled
contactor K1+K2 (Recommended fuse rating)
A
29 (32)
29 (32)
33 (32)
Max operating current heat pump including 4,5 kW
immersion heater, compressor working and enabled
contactor K1+K2 +K3 (Recommended fuse rating)
A
35,5 (32)
35,5 (32)
39,5 (40)
Max operating current 4,5 kW immersion heater,
compressor not working and enabled contactor
K1+K2 +K3 (Recommended fuse rating)
A
19,5 (20)
19,5 (20)
19,5 (20)