Start
Commissioning
Start guide
IMPORTANT
There must be water in the climate system be-fore the
switch is set to „
I
”.
The first time the installation is started a start guide is
started. The start guide instructions state what needs
to carried out at the first start together with a run
through of the installation’s basic settings.
The start guide ensures that start-up is carried out
correctly and cannot be bypassed. The start guide
can be started later in menu 5.7.
During the start-up guide, the reversing valves and
the shunt are run back and forth to help vent the heat
pump.
1. Set switch (SF1) on controller to position "
I
".
2. Follow the instructions in the display's start guide.
If the start guide does not start when you start the
controller , start it manually in menu 5.7.
In order to start the heat pump
1. Turn on the power of the HT 6Split / HT 12Split unit
making sure that the LSplit unit has been properly
connected to the power supply.
2. Follow the instructions displayed in the control-
ler's start-up wizard or start the start-up wizard in
menu 5.7.
ADVICE
See page 38 for a more in-depth introduction to the
installation’s control system (operation,menus etc.).
CAUTION
As long as the start guide is active, no function in con
-
troller will start automatically. The guide will appear at
each restart of controller, until it is deselected on the
last page.
CAUTION
If starting up the system in low outdoor temperatures
and a low heating medium temperature in the central
heating system, the central heating system should be
warmed up first, using the additional heat, to a tem-
perature of about 20 °C.
Operation in the start guide
A
.
Page
Here you can see how far you have come in the start
guide. Scroll between the pages of the start guide as
follows:
1. Turn the control knob until one of the arrows in
the top left corner (at the page number) has been
marked.
2. Press the OK button to skip between the pages
in the start guide.
B
.
Name and menu number
Read what menu in the control system this page of
the start guide is based on. The digits in brackets re-
fer to the menu number in the control system.
If you want to read more about affected menus either
consult the help menu or read the user manual.
C
.
Option / setting
Make settings for the system here.
D
.
Help menu
In many menus there is a symbol that indicates
that extra help is available.
To access the help text:
1. Use the control knob to select the help symbol.
2. Press the OK button..
The help text often consists of several windows that
you can scroll between using the control knob.
Starting without a heat pump
The indoor unit can be used without a heat pump,
i.e only as an electric boiler, to produce heat and hot
water before the heat pump is installed, for example.
Go to menu 5.2 System settings and turn off the heat
pump.
IMPORTANT
Select the auto or manual operation mode when the
indoor unit is to be used again with the heat pump.