56
HT 6Split
HT 12Split
Chapter 9 |
Control
IMPORTANT
Menu 5.3.21 is deactivated in the factory settings. For
this menu function to be active, it is necessary to install
accessory and activate it in the Accessories menu 5.2.4.
IMPORTANT
Menu 5.3.16 is deactivated in the factory settings. For
this menu function to be active, it is necessary to install
accessory and activate it in the Accessories menu 5.2.4
IMPORTANT
Menu 5.3.14 is deactivated in the factory settings. For
this menu function to be active, it is necessary to install
accessory and activate it in the Accessories menu 5.2.4.
IMPORTANT
Menu 5.3.11 is deactivated in the factory settings. For
this menu function to be active, it is necessary to install
accessory Modbus Split and activate it in the Accessories
menu 5.2.4.
IMPORTANT
The contact to the AUX input must be a potential-free
contact (normally open-normally closed).
IMPORTANT
Menu 5.3.12 is deactivated in the factory settings. For
this menu function to be active, it is necessary to in-
stall accessory and activate it in the Accessories menu
5.2.4.
IMPORTANT
After resetting, the start guide will be displayed the
next time the control module is started up, and the set-
tings will be lost.
Menu 5.3.11 - Modbus
For a detailed description of how to program accessories,
refer to the instructions of the individual accessories.
For a detailed description of how to program accessories,
refer to the instructions of the individual accessories.
For a detailed description of how to program accessories,
refer to the instructions of the individual accessories.
Menu 5.3.12 - Exhaust/supply air module
Menu 5.3.14 - F135
For a detailed description of how to program accessories,
refer to the instructions of the individual accessories.
Menu 5.3.21 - flow sensor / energy meter
For a detailed description of how to program accessories,
refer to the instructions of the individual accessories.
Menu 5.3.16 - Humidity sensor
Menu 5.5 - Factory setting service
All settings can be reset (including settings available
to the user) to factory default values here.
Menu 5.6 - Forced control
You can force control the different components in the
control module and any connected accessory in this
menu.
This menu is used for testing individual components of the
HT 6Split / HT 12Split .
Menu 5.4 - Selectable in/outputs
In this menu you can select which input on the input
board (AA3) the external contact function (
page 73
)
can be connected to.
Available inputs on the terminal blocks AUX1-3
(AA3-X6:9-14). The AUX inputs are freely program
-
mable and allow for the introduction of additional
functions using external contacts.
Input AA3-X7 can be programmed according to your
needs.
Possible configurations AA3-X7:
•
Not used,
•
Holiday,
•
Away mode,
•
Alarm output,
•
Hot water recirculation,
•
Ext heat. med. pump
Factory setting: