HT 6Split
HT 12Split
Chapter 9 |
Control
CAUTION
An incorrect set point value may damage the building
in the long term and possibly increase energy con-
sumption.
CAUTION
If no alarm action is selected, it can result in higher
energy consumption in the event of an alarm.
CAUTION
An incorrectly set ventilation flow can damage the
building and may also increase energy consumption
due to the electric heater operation.
IMPORTANT
Menu 5.1.6 is deactivated in the factory settings. For this
menu function to be active, it is necessary to install acces-
sory and activate it in the Accessories menu 5.2.4.
IMPORTANT
The factory settings in menu 5.1.12 are the required set-
tings. Only authorised installers and service technicians
are able to edit these settings!
IMPORTANT
Menu 5.1.5 is inactive in the factory settings. For this
menu function to be active, the accessory must be in-
stalled and activated in the accessories menu. 5.2.4.
Menu 5.1.4 - Alarm actions
Menu 5.1.5 - Fan speed, exhaust.
If “add. heat” is selected and activated in menu 4.2
and the current supply temperature exceeds that cal-
culated using the set point value, the additional heat
will be forced to stop.
Indicate here if you would like the control module to
inform you of the presence of an alarm on the display.
One option is that the heat pump stops producing hot
water and/or reduces the room temperature.
Set the speed from the five different available speeds
for the fan here.
Normal and speed 1-4
Setting range: 0 – 100 %
Factory setting normal:75%
Factory setting speed 1: 0%
Factory setting speed 2: 30%
Factory setting speed 3: 80%
Factory setting speed 4: 100%
Max. diff. add. heat
If the current supply temperature exceeds the sup-
ply calculated using the set point value, the degree
minute value is set to 0. The compressor in the heat
pump stops when there is only a heating demand.
For detailed information on accessory settings, see
the instructions for the given accessory.
Max. diff. compressor
Menu 5.1.6 - Fan speed, supply.
Menu 5.1.12 - Add. heat
Set the speed from the five different available speeds
for the fan here.
The settings in this menu pertain to how the addition-
al heat is controlled.
Max. step
Setting range (binary stepping deactivated): 0 – 3
Setting range (binary stepping activated): 0 – 7
Factory setting max. step: 3
Binary stepping
Setting range: activated / deactivated
Factory settings:
deactivated
Factory setting: add.type: step controlled
Factory setting: positioning: before QN10 (REQUIRED)
Normal and speed 1-4
Setting range: 0 – 100 %
Factory setting normal: 75%
Factory setting speed 1: 0%
Factory setting speed 2: 30%
Factory setting speed 3: 80%
Factory setting speed 4: 100%