42
HT 6Split
HT 12Split
Chapter 9 |
Control
IMPORTANT
In the case of a fuse rating with a smaller value (ap-
plies to the main fuse rating in the house) you can set
this value lower than 16 A. Note, this will reduce the
power of the appliance. Connecting current sensors
is required.
You cannot set this value higher than 20A.
In this menu, you can check the permissible values for
the external sensors. For more information select "?".
6/16 Outdoor temp. sensor check
In this menu, you can choose the settings for the addi-
tional heat (built-in electric module). For more informa-
tion select "?".
Factory settings:
add.type: step controlled
positioning: before QN10
max step: 3
binary stepping: deactivated
fuse size: 16 A
transformation ratio: 300
In this menu, you can select slave devices. For more
information select "?".
Factory settings:
Slave 1: active (EB101)
7/16 Add. heat
8/16 Installed slave devices
The recommended setting values are:
+ 35 for under floor heating systems,
+ 55 for radiator heating.
For detailed information on curve settings, see pt.
“User settings”.
In this menu, set the current date and time. There is
also the option to choose the time display format and
time zone.
In this menu, you can edit the minimum supply tem-
perature of the climate system. For more information
select "?".
Factory settings:
Climate system 1: 20 C
In this menu, you can edit the maximum supply tem-
perature of the climate system. For more information
select "?".
Factory settings:
Climate system 1: 55 C
In this menu, you can edit the heating curve for the HT
6Split / HT 12Split unit. For more information select "?".
Factory settings:
Heating curve: 7
9/16 Time and date
10/16 Min. heat. supply. temp.
11/16 Max. heat. supply. temp.
12/16 Heating curve