802953
98
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Power Fail Recovery
The Power Fail Recovery feature allows the cycle
status to be saved in memory in the event of a power
failure.
If the power failure lasted less than 30 seconds and the
door is locked, the cycle will resume without requiring
the user to press the START (enter) keypad to restart.
If the power failure lasted longer than 30 seconds, the
Power Fail Reset option is turned “ON,” the door is
unlocked, and the duration of the power failure is less
than or equal to the time programmed in the Power
Fail Reset option, the START (enter) keypad will flash
until it is pressed and the cycle will restart from the
point it left off.
If the power failure lasted longer than 30 seconds, the
Power Fail Reset option is turned “OFF,” and the door
is unlocked, the START (enter) keypad will flash one
second on and one second off until it is pressed. The
cycle will restart from the point it left off when
START (enter) is pressed.
If the power failure lasted longer than 30 seconds,
lasted longer than the time programmed in the Power
Fail Reset option, and the Power Fail Reset option is
turned “ON,” the control will flash the START (enter)
keypad one (1) second on and one (1) second off.
When the pad is pressed, the cycle will start a delicate
final high spin.