Testing Machine and Electronic Control Functions
802953
88
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Diagnostic Test Descriptions
Control Software Version Number Test
This option displays the control software version
number. To start test, control must be in the Testing
Mode. Refer to
How to Enter Testing Feature
at the
beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
S XX
” where “
XX
” is the software version
number.
To exit the Software Version Number Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Service Door Opening Test
This option tests the service door switch. To start test,
control must be in the Testing Mode. Refer to
How to
Enter Testing Feature
at
the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
S oP
” when the service door switch is
open and “
S CL
” when the service door switch is
closed.
The service door switch has to be closed for at least
one second and opened for at least a half a second for
the display to change. This test will add a count to the
service door opening counter for the audit and save the
date/time for each opening.
To exit the Service Door Opening Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Coin Vault Opening Test
This option tests the coin vault switch. To start test, the
control must be in the Testing Mode. Refer to
How to
Enter Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show
“
U oP
” when the coin vault switch is open
and “
U CL
” when the coin vault switch is closed.
The coin vault switch has to be closed for at least one
second and opened for at least a half a second for the
display to change. This test will add a count to the coin
vault opening counter for the audit and save the time/
date for each opening.
To exit the Coin Vault Opening Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Coin Drop #1 Input Test
This option tests coin drop #1. To start test, control
must be in the Testing Mode. Refer to
How to Enter
Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
C1XX
”. The “
XX
” will show the number
of coins entered and will increment one for each coin
entered in coin drop #1.
NOTE: Coins entered in test mode will not
increment the total # of coins counter that is
accessed in the audit feature.
To exit the Coin Drop #1 Input Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Coin Drop #2 Input Test
This option tests coin drop #2. To start test, control
must be in the Testing Mode. Refer to
How to Enter
Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
C2XX
”. The “
XX
” will show the number
of coins entered and will increment one for each coin
entered in coin drop #2.
NOTE: Coins entered in test mode will not
increment the total # of coins counter that is
accessed in the audit feature.
To exit the Coin Drop #2 Input Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Coin Drops Header Present Test
(software version “S 02” or higher only)
This option tests the coin drop header connection. To
start test, control must be in the Testing Mode. Refer to
How to Enter Testing Feature
at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show “
CHoP
” when the wiring connection is
open and “
CHCL
” when the connection is closed.
To exit Coin Drops Header Present Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Содержание ST3LXFSP401NW22