9. Audio Signal “AUd”
This option allows the owner to program when the
audio signal will sound.
There are five occasions when a signal may sound
during the washer operation. These five occasions are
listed below:
1.
End of Cycle Signal
By default, the signal is turned off. If turned on,
the signal will sound for three seconds at the end
of a cycle.
2.
Keypad Depression Signal
By default, this signal is turned on and will sound
for a quarter of a second. This signal will sound
each time a keypad is pressed.
3.
Coin Input/Card Insertion Signal
By default, this signal is turned on and will sound
for a quarter of a second each time a coin or card
is entered.
4.
Remove Card Signal (Card Models Only)
By default, this signal is turned on and will sound
one second on and one second off when the
control is prompting for card removal.
5.
Signal for Start
By default, this signal is turned on and will sound
one second on and one second off for 10 seconds
after vend price has been satisfied.
How to Program the Audio Signal
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
Prog
” appears in the
display. Press the START (enter) keypad and
“
AtS1
” will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until “
AUd
” appears in
the display.
4. When “
AUd
” appears in the display press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Audio Signal Programming Value.
5. Locate the desired number in the first column of
Table 4
on the following page.
6. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to increase or decrease the
current number until correct.
For Example: A user might wish to have the signal
sound only when a keypad is pressed. Entering the
number “1” in step 5 would turn off all the options
except KEYPAD. In this instance, the signal would
sound only when a keypad is pressed.
7. Press the START (enter) keypad when the correct
number appears in the display. The next option,
“
CArd
”, will appear in the display.
NOTE: To program
“CArd”
(Card Reader Display
Control), refer to
option 10
. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
>
<
>
<
>
<