© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
89
802953
Door Switch Input Test
This test will display whether the washer door is open
or closed.
To start test, control must be in the Testing Mode.
Refer to
How to Enter Testing Feature
at the
beginning of this section.
To enter, press the START (enter) keypad. If the door
is closed, the display will show “
drCL
”
.
If the door is
open, the display will show “
droP
”.
To exit the test, press the DELICATES 30 (<) keypad.
The control will return to the testing mode.
Door Lock Input Test
This test will display whether the door is locked or
unlocked.
To start test, control must be in the Testing Mode.
Refer to
How to Enter Testing Feature
at
the
beginning of this section.
To enter, close the door and press the START (enter)
keypad. The control will lock the door. If the door is
open, the display will show “
door
”. The door must be
closed to enter test.
If the door is unlocked, the display will show “
drUL
”.
After the door is locked, the display shows “
drLo
” and
turns off power to the door lock. The door will take
approximately one minute to unlock. This sequence is
repeated every time the START (enter) keypad is
pressed.
To exit the test, press the DELICATES 30 (<) keypad.
The control will return to the testing mode.
Pump/Gravity Drain Test
This test turns on the pump/gravity drain output.
To start test, control must be in the Testing Mode.
Refer to
How to Enter Testing Feature
at the
beginning of this section.
To enter, door must be closed. Press the START (enter)
keypad. The control will lock the door and turn on the
pump/gravity drain output. The display will show
“
PunP
” for a pump equipped machine and “
drAi
” for
a gravity drain equipped machine.
To exit the Pump/Gravity Drain Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Show Fill Time Test
This test will display the average fill time. This
average will be calculated by taking the average of the
last 10 fill times.
To start test, control must be in the Testing Mode.
Refer to
How to Enter Testing Feature
at the
beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
FXXX
”
.
The “
XXX
” will be the average
fill time in seconds.
To exit the Show Fill Time Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Temperature Sensor Display Test
This test displays the temperature in degrees Celsius.
To start test, control must be in Testing Mode. Refer to
How to Enter Testing Feature
at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show “
C XX
”. The “
XX
” will be the temperature
in degrees Celsius. If the control senses a shorted
sensor, it will display “
SH
”. If the control senses an
open sensor, it will display “
OP
”.
To exit the Temperature Sensor Display Test, press the
DELICATES 30 (<) keypad. The control will return to
the testing mode.
Start Pulse Test
This option tests the Start Pulse. To start test, control
must be in the Testing Mode. Refer to
How to Enter
Testing Feature
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
StXX
”. The “
XX
” will show the number of
pulses entered. This test will add counts to the total
number of Start Pulses counter. Refer to
Collecting
Audit Information
.
To exit the Start Pulse Test, press the DELICATES 30
(<) keypad. The control will return to the testing
mode.
Содержание ST3LXFSP401NW22