Testing Machine and Electronic Control Functions
802953
86
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Diagnostic (Testing) Mode – Quick Reference Chart
Software Version “S 02” or higher
Test Number
Diagnostic Mode
Display
“d001”
Control Software Version # Test
“SXX”
“d002”
Service Door Opening Test
“SXX”
“d003”
Coin Vault Opening Test
“UXX”
“d004”
Coin Drop #1 Input Test
“C1XX”
“d005”
Coin Drop #2 Input Test
“C2XX”
“d006”
Coin Drops Header Present Test
“CHoP” or “CHCL”
“d007”
Door Switch Input Test
“drCL” or “droP”
“d008”
Door Lock Switch Input Test
“drUL” or “drLo”
“d009”
Pump/Gravity Drain Test
“PunP” or “drAi”
“d010”
Show Fill Time Test
“FXXX”
“d011”
Temperature Sensor Display Test
“C XX”
“d012”
Start Pulse Test
“StXX”
“d013”
Configuration #1 Display Test
“A0XX”
“d014”
Configuration #2 Display Test
“b0XX”
Table 16