Programming Control
802953
36
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
11. Error Code Programming “Err”
This option allows the owner to turn on or turn off
certain errors in the control.
How to Program Error Code Programming
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad until “
Prog
” appears in the
display. Press the START (enter) keypad and
“
AtS1
” will appear in the display.
3. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to scroll through the
programmable options until “
Err
” appears in the
display.
4. When “
Err
” appears in the display, press the
START (enter) keypad. There are six
programmable error code parameters. Refer to
Table 5
.
5. Press the NORMAL 40 ( ) or the DELICATES
COLD ( ) keypad to
select error code.
6. Press the START (enter) keypad when the correct
code appears in the display. The current status
will appear in the display.
NOTE: Press the NORMAL 40 ( ) or the
DELICATES COLD ( ) keypad and then the
START (enter) keypad again to choose a specific
coin error parameter. Refer to
Table 5
.
7. “
oFF
” indicates the option is disabled. “
on
”
indicates the option is enabled. Press the
NORMAL 40 ( ) or the DELICATES COLD ( )
keypad to change the status.
8. Press the START (enter) keypad when the correct
status appears in the display. The next Error Code
Programming option will appear in the display.
NOTE: To program
“CyC-”
(Cycle Programming),
press the DELICATES 30 (<) keypad and refer to
option 12
. To program other options, refer to the
appropriate section.
How to Exit Programming Feature
Press the DELICATES 30 (<) keypad until the control
returns to Ready Mode.
Factory
Default
Setting
“
CErr
”
Coin Error Parameters
“
CEr1
” Coin Error - Determines
if display will show error.
“
on
”
“
CEr2
” Coin Error Penalty - If
enabled, coin error will
erase previous coins
entered and reset the vend
price.
“
oFF
”
“
CEr3
” Coin Drops Header
Present Error - If enabled
and coin drop header is
unplugged, control
ignores coin inputs.
“
on
”
“
E FL
”
Fill Error
“
on
”
“
E ub
”
Unbalance Error
“
on
”
“
E oP
”
Open Thermistor Error
“
on
”
“
E SH
”
Shorted Thermistor Error
“
on
”
“
E Ht
”
Heater Error
“
on
”
Table 5
>
<
>
<
>
<
>
<
>
<