Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
c. Remove four screws and lockwasher holding
timer and plate to timer case. Refer to Figure 8.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
d. Pull timer and plate out of timer case as far as
wires will permit. Refer to Figure 8.
e. Remove screw, lockwasher and locknut
holding ground wires to timer. Refer to
Figure 8.
f. Disconnect wires from timer. Refer to Figure 8.
NOTE: Refer to the appropriate wiring diagram
when rewiring the timer.
g. Remove cap screw, lockwashers and nut
holding timer case to control hood. Refer to
Figure 7.
h. Remove two screws from bottom edge of the
front panel. Refer to Figure 13.
i. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top. Refer to Figure 13.
j. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
k. Remove two cabinet top hold-down screws.
Refer to Figure 14.
l. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 15.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind dryer while servicing.
m. Carefully withdraw the wire harness through
hole in cabinet top and lift the entire cabinet top
assembly off the hold-down brackets. Refer to
Figure 15.
n. Lay the cabinet top assembly flat, remove two
carriage bolts, washers, lockwashers and nuts
holding meter case to cabinet top and remove
meter case. Refer to Figure 8.
o. Remove screw holding rear of case to cabinet
top and remove case. Refer to Figure 8.
31. CABINET TOP – NONMETERED MODELS
a. Remove two control panel attaching screws and
lift assembly off cabinet top. refer to Figure 7.
b. Disconnect all wires to temperature switch,
push-to-start switch and indicator light and
remove ground clip and screw holding ground
wire to cabinet top and control panel. Refer to
Figure 5.
NOTE: Refer to the appropriate wiring diagram
when reconnecting wires.
c. Remove four screws and lockwasher holding
timer and plate to timer case. Refer to Figure 8.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
Figure 15
DRY857S
CABINET TOP
HINGES
BRACE