![Alliance Laundry Systems ZE1010-1502 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/alliance-laundry-systems/ze1010-1502/ze1010-1502_service-manual_2901222036.webp)
62631
37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39. FRONT PANEL AND PANEL SEAL
Refer to Figure 13
a. Remove two screws from the bottom edge of
the front panel.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring switch.
d. Remove front panel seal from flange around
inside of door opening.
NOTE: Be sure seal is properly positioned when
installing on front panel.
40. DOOR SWITCH
Refer to Figure 13
a. Remove two screws from the bottom edge of
the front panel.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Depress tabs on top and bottom of switch and
push out of front panel. Refer to Figure 18.
41. STRIKER CATCH
Refer to Figure 13
a. Remove two screws from the bottom edge of
the front panel.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Depress tabs on top and bottom of catch and
push out of front panel. Refer to Figure 18.
To Test Door Switch
1. Set meter to read Ohms and apply meter probes
on switch terminals with door closed. You
should get “zero” reading.
2. Open door. Meter should read “infinite.”
Figure 18
DRY1056S
DOOR
SWITCH
TABS