Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
62. CABINET
a. On Card Reader Models, remove panel lock (if
present). Refer to Figure 7.
NOTE: Several turns of the key may be required to
remove panel lock.
b. Remove two control panel attaching screws and
lift assembly off cabinet top.
c. Disconnect all wires to temperature switch,
PUSH-TO-START switch and INDICATOR
LIGHT and remove ground clip and screw
holding ground wire to cabinet top and control
panel.
NOTE: Refer to the appropriate wiring diagram
when reconnecting wires.
d. Metered Models:
(1) Insert key in service door lock on top of
meter case and unlock door. Refer to
Figure 10.
(2) Lift rear end of service door approximately
45° off meter case to disengage notched
tabs with internal rib at top of meter case.
Refer to Figure 10.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about a 45° angle in order to engage notched tabs
with internal rib at top of meter case.
(3) Disconnect accumulator wires at
connectors. Refer to Figure 10.
Figure 38
DRY1807S
DRY950S
CABINET TOP
HINGES
TERMINAL BLOCK
TERMINAL BLOCK
BRACKET
TERMINAL BLOCK
ATTACHING SCREW
Through Serial No. S6271975XG
Starting Serial No. S6271976XG
TERMINAL
BLOCK
ATTACHING
SCREWS
BRACKET
SCREWS
GROUND
WIRE