62631
9
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 3
Troubleshooting
IMPORTANT: Refer to appropriate model wiring diagram for aid in testing dryer components.
1. MOTOR DOES NOT RUN
POSSIBLE CAUSE
TO CORRECT
Electrical power off, fuse blown, or power cord not
plugged in.
• Be sure to check both fuses on electric models.
Loading door not closed or inoperative door switch. • Close door or test switch and replace if inoperative.
Motor overload protector has cycled.
• Wait two or three minutes for overload protector to reset.
If protector cycles repeatedly, refer to Paragraph 2.
Timer improperly set.
• Reset timer.
Inoperative motor switch.
• Test switch and replace if inoperative.
Start circuit not completed.
• Press start switch button, or test switch and replace if
inoperative.
Inoperative motor.
• Test motor and replace if inoperative.
Inoperative timer – nonmetered models.
• Test timer and replace if inoperative.
Inoperative accumulator – metered models.
• Test accumulator and replace if inoperative.
Accumulator not being activated.
• Install slide extension.
Broken, loose, or incorrect wiring.
• Refer to appropriate wiring diagram.
Motor centrifugal switch sticky or plugged with
lint.
• Remove dust or lint and spray with “Slyde”, No. 131P4,
to clean and lubricate.