To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 7
Gas Burner Conversion Procedures
458P3 L.P. Gas Conversion Kit consists of:
Gas Input - 25,000 BTU/HR
NOTE: When converting the dryer gas valve to L.P.
gas, be sure the incoming gas supply line is equipped
with a pressure regulator (located ahead of the
dryer) that will maintain the gas supply to the dryer
at 10 ± 1.5 inches (25.4 ± 3.81 cm) water column
pressure and a vent to the outdoors must be
provided. Remove pressure tap pipe plug and check
gas pressure by connecting a “U” tube manometer
(or similar pressure gauge) to the pressure tap.
Refer to Figure 41.
WARNING
This conversion kit is to be installed by AUTHORIZED DEALERS or DISTRIBUTORS on their
premises and in accordance with the manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
W312
1 - 58754
Block - Open Plug
1 - 60418
Burner Orifice Spud (Metal stamped
#53)
1 - 60513
Conversion Plate
1 - 60517
Valve Converted to L.P. Gas Sticker
2 - 60518
L.P. Gas Stickers
Figure 41
55"
DRY962S
Block Open Plug
Burner Orifice Spud
#53
DRY961S
MANOMETER
10 ± 1.5
INCHES
PRESSURE
TAP