![Alliance Laundry Systems ZE1010-1502 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/alliance-laundry-systems/ze1010-1502/ze1010-1502_service-manual_2901222040.webp)
62631
41
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: The holding and booster coil, and secondary
coil can be replaced individually.
b. Burner Tube, Igniter and Bracket
NOTE: Burner tube and igniter can be removed
without removing gas valve and bracket.
(1) Remove one screw from right side of
burner housing holding burner tube in
place. Refer to Figure 23.
(2) Gently move burner tube toward rear of
dryer to disengage tab from slot on left side
of burner housing. Refer to Figure 19.
(3) Carefully rotate burner tube and igniter
counterclockwise so tab is at 8 o’clock
position.
(4) Move air shutter end of burner tube slightly
to right and CAREFULLY remove burner
tube and igniter assembly out through front
of dryer.
(5) Remove screw holding the igniter and
bracket to the burner tube and remove
igniter and bracket. Refer to Figure 22.
IMPORTANT: Use care in removal so as not to
damage or break igniter as it is very fragile.
IMPORTANT: Handle igniter by grasping the
white ceramic portion or bracket only. DO NOT
handle silicon carbide portion of igniter with hands
or allow any oil, grease or other foreign material to
contaminate it. Oil, grease and other impurities or
hairline cracks will cause the igniter to burn out.
c. Sensor – Refer to Figure 19.
(1) Remove two screws from the bottom edge
of the front panel. Refer to Figure 13.
(2) Swing the bottom of the panel away from
the dryer to disengage hold-down clips and
guide lugs from cabinet top. Refer to
Figure 13.
(3) Disconnect wires from door switch. Refer
to Figure 18.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
(4) Remove wires from sensor terminals. Refer
to Figure 19.
(5) Remove screw holding sensor to burner
housing. Refer to Figure 19.
Figure 22
DRY952S
CARBORANDUM
IGNITER AND
BRACKET
ATTACHING
SCREW
ATTACHING
SCREW
IGNITER AND
BRACKET
NORTON
IGNITER AND
BRACKET
To Test Igniter
(Gas Models)
Refer to Figure 22.
This procedure can be performed on workbench
if gas valve, igniter, burner tube and burner
housing have been removed from dryer.
1. Disconnect igniter wires at disconnect block.
Refer to Figure 19.
2. Set test meter to read OHMS and put meter
probes on terminals of igniter wires.
3. Meter should register an Ohm reading of at least
40 Ohms. If meter does not register any Ohms or
less than 40 Ohms, replace the igniter.
IMPORTANT: Always examine all wires,
terminals and connectors to be sure wiring is
proper before replacing any components.