To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
29. METER CASE
a. Remove two control panel attaching screws and
lift assembly off cabinet top. Refer to Figure 7.
b. Disconnect all wires to temperature switch,
PUSH-TO-START switch and INDICATOR
LIGHT and remove ground clip and screw
holding ground wire to cabinet top and control
panel. Refer to Figure 5.
NOTE: Refer to the appropriate wiring diagram
when reconnecting wires.
c. Insert key in service door lock on top of meter
case and unlock door. Refer to Figure 10.
d. Lift rear end of service door approximately 45°
off meter case to disengage notched tabs with
internal rib at top of meter case.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about a 45° angle in order to engage notched tabs
with internal rib at top of meter case.
e. Disconnect accumulator wires at connectors.
Refer to Figure 10.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
f. Remove hex head ground screws holding green
ground wire to accumulator mounting bracket.
Refer to Figure 10.
g. Remove one hex head cap screw (right rear
corner) holding meter case to cabinet top. Refer
to Figure 12.
h. Remove nut, lockwasher and screw holding
meter case to right end of control hood. Refer to
Figure 12.
Figure 12
DRY1808S
CAPSCREW
METERCASE
SCREW
CARRIAGE
BOLTS