62631
33
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
d. Pull timer and plate out of timer case as far as
wires will permit. Refer to Figure 8.
e. Remove screw, lockwasher and locknut
holding ground wires to timer. Refer to
Figure 8.
f. Disconnect wires from timer. Refer to Figure 8.
NOTE: Refer to the appropriate wiring diagram
when rewiring the timer.
g. Remove cap screw, lockwashers and nut
holding timer case to control hood. Refer to
Figure 7.
h. Remove two screws holding control hood to
cabinet top and lift hood off rear tabs. Refer to
Figure 7.
i. Remove two screws from bottom edge of the
front panel. Refer to Figure 13.
j. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top. Refer to Figure 13.
k. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
l. Remove two cabinet top hold-down screws.
Refer to Figure 14.
m. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 15.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind dryer while servicing.
n. Carefully withdraw the wire harness through
hole in cabinet top and lift the entire cabinet top
assembly off the hold-down brackets. Refer to
Figure 15.
o. Lay the cabinet top assembly flat, remove two
carriage bolts, washers, lockwashers and nuts
holding meter case to cabinet top and remove
meter case. Refer to Figure 12.
p. Remove screw holding rear of case to cabinet
top and remove case. Refer to Figure 8.
q. Remove brace from underside of cabinet top by
swinging one end toward front or rear. Refer to
Figure 15.
32. CABINET TOP – METERED MODELS
a. Remove two control panel attaching screws and
lift assembly off cabinet top. Refer to Figure 7.
b. Disconnect all wires to temperature switch,
push-to-start switch and indicator light and
remove ground clip and screw holding ground
wire to cabinet top and control panel. Refer to
Figure 5.
NOTE: Refer to the appropriate wiring diagram
when reconnecting wires.
c. Insert key in service door lock on top of meter
case and unlock door. Refer to Figure 10.
d. Lift rear end of service door approximately 45°
off meter case to disengage notched tabs with
internal rib at top of meter case. Refer to
Figure 10.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about a 45° angle in order to engage notched tabs
with internal rib at top of meter case.
e. Disconnect accumulator wires at connectors.
Refer to Figure 10.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
f. Remove hex head ground screw holding green
ground wire to accumulator mounting bracket.
Refer to Figure 10.
g. Remove one hex head cap screw (right rear
corner) holding meter case to cabinet top. Refer
to Figure 12.
h. Remove nut, lockwasher and screw holding
meter case to right end of control hood. Refer to
Figure 12.
i. Remove two screws holding control hood to
cabinet top and lift hood off rear tabs. Refer to
Figure 7.