55. CYLINDER BELT
a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 13.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 13.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Disengage belt from motor and idler pulleys,
e. Remove four screws holding bulkhead to front
flange of cabinet. Lift complete bulkhead
assembly out of slots in cabinet. Refer to
Figure 32.
IMPORTANT: During reinstallation of front
bulkhead, be sure that air duct is properly
positioned with the flange inside of the felt seal on
the exhaust fan cover.
f. While supporting cylinder, carefully remove
belt off cylinder.
NOTE: When installing belt, be sure belt is
properly installed on motor and idler pulleys, and is
on the correct side of the idler lever. Refer to
Figure 28. Belt must be positioned around cylinder
between center and rear baffle screws with the
ribbed surface against the cylinder. After installing
belt, rotate cylinder manually to check that belt is
properly aligned.
Figure 33
DRY861S
CYLINDER GLIDE
ATTACHING SCREWS
SPRING
SEAL MUST BE
POSITIONED UNDER
FLANGED EDGE
FELT
SEAL
SEAL
STRAP
(Installed
with
cupped
surface
against
seal)
BULKHEAD