Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
i. Motor Pulley and Idler Pulley Assemblies
(1) Refer to Figure 30 for motor and idler
pulley removal.
j. Impeller and Housing
(1) Remove screw holding ground wire (if
present) to exhaust fan cover. Refer to
Figure 27.
NOTE: Ground wire must be routed as shown in
Figure 2. Refer to SECTION IV “Grounding.”
(2) Remove screws holding cover to housing.
Refer to Figure 27.
(3) Hold motor pulley securely and unthread
impeller from motor shaft (right hand
thread). Use a 7/8 inch, 6 point socket to aid
in the removal of the impeller.
(4) Remove three screws and washers holding
the exhaust housing to the motor mounting
bracket. Refer to Figure 31.
k. Motor
(1) Disconnect wires from motor switch. Refer
to Figure 30.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.
(2) Disconnect ground wire from motor. Refer
to Figure 30.
(3) Pry two motor clamps off using a
screwdriver. Refer to Figure 30. Then lift
motor out of mounting bracket.
NOTE: When replacing motor, motor switch
location should be at 10 o’clock position with the
positioning tab on the motor engaged with the notch
in the motor bracket. Refer to appropriate wiring
diagram when rewiring motor switch leads.
54. FRONT BULKHEAD ASSEMBLY
a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 13.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 13.
c. Disconnect wires from door switch. Refer to
Figure 30
DRY860S
SETSCREW
MOTOR
PULLEY
IDLER
PULLEY
IDLER
SPRING
TRU-ARC
RING
GROUND
WIRE
MOTOR
CLAMP
MOTOR