46
62631
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
52. EXHAUST DUCT
a. Disconnect electric power, vent (and gas line if
necessary) and move unit to gain access to rear
of dryer.
b. Remove screw holding bracket on exhaust duct
to rear of cabinet. Refer to Figure 26.
c. Pull duct out through rear of cabinet.
53. MOTOR AND EXHAUST ASSEMBLY
a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 13.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 13.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Remove lint filter. Refer to Figure 16.
NOTE: When installing lint filter, be sure to install
the filter with the word “FRONT” facing the front
of the dryer.
e. Remove screws holding air duct to front
bulkhead and remove air duct. Refer to
Figure 25.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
air duct. Refer to Figure 24.
f. Disconnect wires from thermostats. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats or thermostat and heater.
Figure 26
DRY1059S
EXHAUST
DUCT
SCREW
GROUND
SCREW
ACCESS
PLATE
MOUNTING BRACKET
ATTACHING SCREWS
Figure 27
DRY1058S
COVER ATTACHING
SCREWS
EXHAUST FAN
COVER
MOTOR MOUNT
ATTACHING SCREWS