background image

Содержание FLSG62MRFS4

Страница 1: ...beauty salons etc For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life ll_e aa_ lne or DO not store or _q r other flammable vapors and liquid in the vicinity ol this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Страница 2: ...cord is installed on laundry center OUTLET RECEPTACLE NEMA I0 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power su py o_c i c iil_ when I lamdy erq r F _ installed position NEMA 10 30R NEMA 14 30R GAS Laundry Center CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximum time delay fuse or circuit breaker POWER SUPPLY 3 wire 120 volt single phase 60 Hz ...

Страница 3: ...he flow of air Explosion hazard Do not install the dryer where gasoline or other flammables are kept or stored If the dryer is installed in agarage it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death explosion fire or burns t The exhaust system back pressure MUST not exceed 0 6 inches 52 cm of water column measured with an inclined manometer at the point ...

Страница 4: ...l be installed in the same closet as the Gas laundry center 3 Your taundry center needs the space around it for proper ve_ liL tlo DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET WITH A SOLID DOOR 4 A minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A touvered d...

Страница 5: ...pacer block should be retained SHIPPING BLOCKS 47 IN 119 38 CM PLASTIC SPACER BLOCK 30_13 16 IN 78 26 CM 1 7 8 IN 4 76 CM _ 4 13116 IN 12 22 CM 11 7l 16 IN 29 05 CM 4 5 Return laundry center to an upright position Remove Ca foam tub blocking pad b foam shipping blocks from rear of unit c tape from dryer door d foam dryer support pads e inlet hoses From the back of the washer remove the wire shippi...

Страница 6: ... properly grounded The laundry center MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor MUST be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Canadian ELECTRICLaundry Center J Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a lice...

Страница 7: ...Terminal erminal Block Black White 7 Attach the red and black wires from the power cord to the outer brass colored terminals on the terminal block Tighten both screws securely 8 Tighten the screws securing the cord restraint firmly against the power cord 9 Reinstall the terminal block access cover INSTALLATION Run some water from the hot and cold faucets to flush the water lines and remove particl...

Страница 8: ...t nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 13 Reinstall the dryer front access panel 14 Runthe washer and dryer through a cycle Check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of aic If the burner does not light within 45 seconds the first time the dryer is turned on the safety swi...

Отзывы: