System Interconnections
18
Agilent E5505A User’s Guide
403
Figure 309
E5505A system connections with test set option 201
+23 dBm
1.2 -26.5 GHz
+10 dBm
50 kHz -1600 MHz
MAXIMUM POWER
20 mA MAX
TUNE VOLTAGE
OUT OF LOCK
<100 kHz
ANALYZER
ANALYZER
RF ANALYZER
PHASE DET OUTPUT
MONITOR
+15 dBm MIN
50 kHz - 1600 MHz
+7 dBm MIN
1.2 - 26.5 GHz
REF INPUT
ERR
ACT
STATUS
SRQ
TLK
LSN
GPIB
RMT
NOISE
0.01 Hz - 100 MHz
1 V Pk
50
50 kHz-1600 MHz
INPUT
SIGNAL
POSSIBLE
SIGNAL INPUT
<100 MHz
50
1.2-26.5 GHz
+10 dBm
MAXIMUM POWER
50 kHz -1600 MHz
+23 dBm
MAXIMUM POWER
+30 dBm
OUTPUT POWER
POWER
N5500A Opt 201
Test Set
1.2-26.5 GHz
W SIGNAL
+23 dBm
OUTPUT POWER
POSSIBLE
+30 dBm
OUTPUT POWER
POSSIBLE
AM NOISE
OUTPUT
RF ANALYZER
2.4 - 25.8 GHz
W LO
IF
5 -1500 MHz
10 VOLTS MAX
CONTROL
VOLTAGE
5 MHz - 26.5 GHz
SIGNAL
INPUT
RMT LSN TLK SRQ
ERR
ACT
STATUS
GPIB
ATTENUATOR
+30 dBm MAX WITH
+10 dBm + ATTEN
MAXIMUM POWER
0 VDC MAX
SIGNAL INPUT
POWER
N5507A
5 MHz-26.5 GHz
Microwave Downconverter
Test set Opt. 201
Spectrum analyzer
Optional reference
signal generator
E5500 software
License key
PC-Digitizer card
Digitizer
input
To test set
rear panel
CHIRP source
Digitizer
output
Optional frequency
counter
Oscilloscope
(recommended)
GPIB
GPIB
Indicates optional cable
NOTE:
Display
Test set Opt. 201
Spectrum
analyzer
To PC
digitizer
To reference
source (optional)
To oscilloscope or
counter monitor
(optional)
DC out
tune voltage
(optional)
E5505a_opt201_conn_dia
14 Apr 04 rev 1
Downconverter
Downconverter
50
Ω
load
Signal input
to be
downconverted
Downconverted
output to test set
signal input
+23 dBm
1.2 -26.5 GHz
+10 dBm
50 kHz -1600 MHz
MAXIMUM POWER
20 mA MAX
TUNE VOLTAGE
OUT OF LOCK
<100 kHz
ANALYZER
ANALYZER
RF ANALYZER
PHASE DET OUTPUT
MONITOR
+15 dBm MIN
50 kHz - 1600 MHz
+7 dBm MIN
1.2 - 26.5 GHz
REF INPUT
ERR
ACT
STATUS
SRQ
TLK
LSN
GPIB
RMT
NOISE
0.01 Hz - 100 MHz
1 V Pk
50
50 kHz-1600 MHz
INPUT
SIGNAL
POSSIBLE
SIGNAL INPUT
<100 MHz
50
1.2-26.5 GHz
+10 dBm
MAXIMUM POWER
50 kHz -1600 MHz
+23 dBm
MAXIMUM POWER
+30 dBm
OUTPUT POWER
POWER
N5500A Opt 201
Test Set
1.2-26.5 GHz
W SIGNAL
+23 dBm
OUTPUT POWER
POSSIBLE
+30 dBm
OUTPUT POWER
POSSIBLE
AM NOISE
OUTPUT
RF ANALYZER
2.4 - 25.8 GHz
W LO
IF
5 -1500 MHz
10 VOLTS MAX
CONTROL
VOLTAGE
5 MHz - 26.5 GHz
SIGNAL
INPUT
RMT LSN TLK SRQ
ERR
ACT
STATUS
GPIB
ATTENUATOR
+30 dBm MAX WITH
+10 dBm + ATTEN
MAXIMUM POWER
0 VDC MAX
SIGNAL INPUT
POWER
N5507A
5 MHz-26.5 GHz
Microwave Downconverter
PC
Содержание E1420B
Страница 24: ...24 Agilent E5505A User s Guide ...
Страница 46: ...46 Agilent E5505A User s Guide 2 Introduction and Measurement ...
Страница 128: ...128 Agilent E5505A User s Guide 5 Absolute Measurement Fundamentals ...
Страница 226: ...226 Agilent E5505A User s Guide 7 Residual Measurement Fundamentals ...
Страница 322: ...322 Agilent E5505A User s Guide 13 Baseband Noise Measurement Examples ...
Страница 340: ...340 Agilent E5505A User s Guide 14 Evaluating Your Measurement Results ...
Страница 358: ...358 Agilent E5505A User s Guide 15 Advanced Software Features ...
Страница 386: ...386 Agilent E5505A User s Guide 16 Reference Graphs and Tables ...
Страница 392: ...392 Agilent E5505A User s Guide 17 System Specifications ...
Страница 404: ...404 Agilent E5505A User s Guide 18 System Interconnections ...
Страница 452: ...452 Agilent E5505A User s Guide 20 PC Digitizer Performance Verification ...
Страница 466: ...466 Agilent E5505A User s Guide 21 Preventive Maintenance ...