Troubleshooting
4
2000/3000 X-Series Oscilloscopes Service Guide
85
6
Re- connect the interboard supply cable as shown in the
following figure.
Figure 14
Setup for troubleshooting internal assemblies
Other advice:
•
Place the front deck in a cover or rest it on a cloth to
prevent scuffing the front panel knobs.
•
Because of the short length of the interboard supply
cable, elevate the rear deck to prevent strain on the
cable.
7
Make sure the keyboard cable, display cable, display
backlight power cable, and all other cables are properly
connected.
C A U T I O N
MAKE SURE EARTH GROUND IS MAINTAINED FOR THE FRONT DECK !
For example, connect a cable with alligator clips between the rear deck chassis
and the front deck chassis, or connect a BNC cable from one of the BNCs on the
system board to a known grounded BNC on your workbench.