VistaKey Installation Guide
3–4
indicates a card not linked to a user. If the card was linked to a user, the user number
would be displayed.
If an access point shows up incorrectly (e.g., you tested access points (VistaKey
addresses) 1 and 2 but the log shows the zone for access point 1 twice), check the
address switch setting in the VistaKey for the access point that is missing. If an access
point test is missing entirely, recheck the system wiring.
g. Press [
✲
] on the keypad to exit the Log View Mode.
The quick installation is complete and the access point(s) are ready to be programmed into
the alarm panel control using the procedures provided in Section 5: Programming.
+
POLE Door Strike/Mag Coil
DATA 1 (WHITE)
DATA 0 (GREEN)
+5V
GND
TRIGGER
+12V (RED)
TO ALARM SYSTEM
CONTROL PANEL
POLLING LOOP TERMINALS.
ZONE C (General)
ZONE A (DSM)
ZONE B (RTE)
POLLING LOOP -
14V MAX
POLLING LOOP +
GND
GND
GND
N/O DOOR STRIKE POWER
TO TB1, 11 OR 12
N/C MAG COIL POWER
2
3
4
5
6
7
8
11 12
2 3 4 5 6 7 8 9 10
1
RELAY CONTACT RATINGS:
3A @ 28VDC MAX. (RESISTIVE LOAD)
TB 1
TB 3
1
READER INTERFACE CABLE
10K
EOLR
10K
EOLR
10K
EOLR
GND (BLACK)
RDR LED (ORANGE)
NO
CONNECTION
+ 12 VDC TO ONLY
ONE OF THESE INPUTS.
(FROM TB1-1)
+
_
VISTAKEY
+
+
+
+
+
+
+
+
+
+
+
POWER SUPPLY
2 3 4 5 6 7 8 9 10
1
CONNECT TO
24 HOUR OUTLET
TRANSFORMER
N8167
18 VAC
50VA
+
-
OPTIONAL
12V
7 AHR
BAT
K1
DOOR
CONTROL
RELAY
PROXIMITY
READER
5365BGP
WARNING: POWER SUPPLY TERMINAL 3 IS COMMON
TO THE POWER SUPPLY GROUND PLANE AND
MUST NOT BE CONNECTED.
FAILURE TO HEED THIS WARNING MAY CAUSE A
GROUND FAULT IN THE VISTA FIRE/BURGULARY SYSTEM.
ADDRESS SELECT
SWITCH POSITIONS:
1-9 = ACCESS POINT 1-9
A = ACCESS POINT 10
B = ACCESS POINT 11
C = ACCESS POINT 12
D = ACCESS POINT 13
E = ACCESS POINT 14
F = ACCESS POINT 15
SUPPLIED TRANSIENT SUPPRESSION DEVICE.
BEFORE INSTALLING,CHECK DOOR/STRIKE
MAG LOCK DIRECTIONS.
NOTES:
•
Local Power and door strike/mag lock power must be supplied from the VistaKey-SK for UL installations.
•
Observe the color coding of your reader if not using the ADEMCO reader.
•
The use an optional battery on the power supply has not been approved for UL installations.
Figure 3-1: VistaKey Wiring