c. Press 0 on the keypad. The keypad displays
:
ALARM EVENT LOG
TYPE CCC UUU
d. Press 3 on the keypad repeatedly until the keypad displays:
ALL EVENT LOG
TYPE CCC UUU
e. Press 8 on the keypad. The keypad display shows the most recent event in the log.
f. Press 1 on the keypad to step back through the event log to verify that all access points
tested are in the log. The first line of the log provides a partition number, date, and
time. The second line of the display for the access point test shows “ACS GRT” or “EGR
GRT” followed by a 3-digit zone number and user number of U999. Note that U999
indicates a card not linked to a user. If the card was linked to a user, the user number
would be displayed.
If an access point shows up wrong (e.g., you tested access points (VistaKey addresses) 1
and 2, but the log shows the zone number for access point 1 twice), check the address
switch setting in the VistaKey for the access point that is missing. If an access point
test is missing entirely, recheck the system wiring.
g. Press the [
✲
] on the keypad to exit the Log View Mode.
The installation is complete and the access point(s) are ready to be programmed into the
alarm control panel using the procedures provided in Section 5 – Programming.