VistaKey Installation Guide
3–2
e. Local +12V supply lead to the N/C relay terminal 11 (if a mag lock is being used); OR
to the N/O relay terminal 12 (if a door strike is being used).
When installing a VistaKey-SK, make this connection to terminal 11 or 12 from
VistaKey TB1 terminal 1.
7. Connect the (–) polling loop and (+) polling loop leads (from the alarm control panel) to
terminals 4 and 3, respectively.
8. Set the Address Select switch to the desired access door number (1-15).
9. Repeat steps 2 through 8 for each VistaKey being installed.
10. When installing a VistaKey-SK, connect the transformer output to terminals 1 and 2 of
the power supply.
11. Turn on the local +12V to the module by plugging in the VistaKey-SK power transformer.
The Reader will beep and its red LED should remain on. (If the LED is blinking yellow,
the state of the DSM switch needs to be temporarily reversed. This may be accomplished
by opening the door if closed, or closing the door if opened, until the testing of this access
point is completed as described below.)
Mapping VistaKey Zones for Test
To prepare the VistaKey and panel for testing, VistaKey Zones must be mapped into panel
zones. To map VistaKey zones into panel zones, perform the steps below.
1. Enter the #93 Menu Mode Programming mode in the alarm
system in accordance with the procedures provided in your
alarm system manuals. The keypad displays:
ZONE PROG?
1 = YES 0 = NO
2. Press 1 for zone programming. The keypad displays:
Set to Confirm?
1 = YES 0 = NO
3. Press 1 to Confirm. The keypad displays:
ENTER ZONE NO.?
000 = QUIT
4. Enter a 3-digit zone number for the access point (e.g., 100).
5. Press [
✲
] twice. The keypad displays:
100 ZONE RESPONSE
6. Enter a 2-digit response type such as 01 (Entry/Exit). Press [
✲
] to accept the entry.
7. Press the [
✲
] repeatedly until the keypad displays:
100 INPUT TYPE
8. Enter 11 (DSM) and then press [
✲
] to accept the entry. The
keypad displays:
100 Access Point
(01-15)
9. Enter a 2-digit access point number corresponding to the access point to be tested. Press
[
✲
] to accept the entry.
10. Press the [
✲
] repeatedly until the keypad displays:
ENTER ZONE NO.?
000 = QUIT
11. Enter 000 and then press the [
✲
] to accept the entry. The
keypad displays:
QUIT MENU MODE?
1 = YES 0 = NO
0
12. Press 1 to quit the menu mode and then enter #99 to exit programming.