Section 4 – Detailed Installation
4–7
supply. Then, connect the transformer to terminals 1 and 2 of the power supply and
plug the transformer into a 24-hour outlet.
When power is connected, the reader will beep and its red LED should remain on. (If the
LED is blinking yellow, the state of the DSM switch needs to be temporarily reversed. This
may be accomplished by opening the door if closed, or closing the door if opened, until the
testing of this access point is completed as described below.)
3. Re-install the VistaKey module front cover and, if you are installing a VistaKey-SK, close
the door on the VistaKey-SK cabinet.
Mapping VistaKey Zones for Test
To prepare the VistaKey and panel for testing, VistaKey Zones must be mapped into panel
zones. To map VistaKey zones into panel zones, perform the following steps:
1. Enter the #93 Menu Mode Programming mode in the alarm system in accordance with
the procedures provided in your alarm system manuals. The keypad displays:
ZONE PROG?
1 = YES 0 = NO
2. Press 1 for zone programming. The keypad displays:
Set to Confirm?
1 = YES 0 = NO
3. Press 1 for Confirm. The keypad displays:
ENTER ZONE NO.?
000 = QUIT
4. Enter a 3-digit zone number for the access point (e.g., 100).
5. Press the [
✲
] on the keypad twice. The keypad displays:
100 ZONE RESPONSE
6. Enter a 2-digit response type such as 01 (Entry/Exit). Press the [
✲
] to accept the entry.
7. Press the [
✲
] repeatedly until the keypad displays:
100 INPUT TYPE
8. Enter 11 (DSM) and then press [
✲
] to accept the entry. The keypad displays:
100 Access Point
(01-15)
9. Enter a 2-digit access point number corresponding to the access point to be tested. Press
[
✲
] to accept the entry.
10. Press the [
✲
] repeatedly until the keypad displays:
ENTER ZONE NO.?
000 = QUIT
11. Enter 000 and then press the [
✲
] to accept the entry. The keypad displays:
QUIT MENU MODE?
1 = YES 0 = NO
0
12. Press 1 to quit the menu mode and then enter #99 to exit programming.