ADASH Ltd.
Adash 4400 – VA4Pro
For further technical and contact information visit www.adash.eu, email: [email protected]
99
The Stethoscope
This mode enables listening of vibrations. Use the standard headphones and connect them to the audio output
on top panel.
Select the Stethoscope mode and push OK. The 4 displays appear. Push START. Each input signal level will
be displayed.
The TRUE PEAK level is displayed. By buttons on the left side you choose the channel for listening. The
volumes buttons are on right side.
The delay of audio output
Because all signal conditioning is digitally arranged, the delay of signal appears. Typically the delay is 1 sec.
You can clearly test to knock to the sensor and you will listen this knock after the delay time.
Playback Settings
For Playback speed settigs push Playback Settings button and select the value.