ADASH Ltd.
Adash 4400 – VA4Pro
For further technical and contact information visit www.adash.eu, email: [email protected]
48
If the tacho was not used (the measurement does not contain the speed information), then move the cursor to
the speed position. The bearing fault frequencies will be displayed according the cursor position.
Orders Table - on, off
the order values table
Statistics Table
the basic statistic values of trend are displayed:
n
number of measurements in trend
EX
mean value (arithmetic average)
σ
(sigma)
deviation average
Xmax
maximum value
Xmin
minimum value
Xmax-Xmin
the interval of measured values
Primary Cursor - when the Global/Cursor Type is set to max, then is required to select the quantity (graph), to
which will be this max searching function applied
amplitude, phase, coherence
for frequency response (Frf)
X, Y
for orbit
View (center line)
center line
standard 2D center line view, available only for View Trend
AB
two DC values for View Actual or two trends for View Trend
XY
data transferred to X and Y axes
View (frf)
ampl, phase
real, imag
nyquist
amplitude
phase
coherence
time
amplitudes
View (1x amp+phase) available only for trend
aps_t
the trends of amplitude, phase and speed related to time of measurement