ADASH Ltd.
Adash 4400 – VA4Pro
For further technical and contact information visit www.adash.eu, email: [email protected]
67
New project
Push the Project button and select the New item. Enter the name of project. The new project is added to the list
of projects and it is selected (active in dark color). Press OK, it will be opened. The list of basic properties
appears. Define your values and press OK.
Balancer Settings
All project properties are defined under this button. When you push it, the menu with several items appears.
Basic Settings
Planes
single, dual
plane(s) balancing
Image
selection of machine image, different images are available for single and dual plane balancing
Look
left, right
view direction (only for single plane balancing)
Rotation
CW, CCW
clockwise or counterclockwise
Inputs
single, dual
one or two AC inputs (sensors) can be used (only for dual planes balancing)
Channel
1-4
the number of AC input, which will be used for sensor mounted on the bearing
(only for single plane balancing)
Channel A
1-4
the number of AC input, which will be used for sensor mounted on the bearing A
(only for dual planes balancing)
Channel B
1-4
the number of AC input, which will be used for sensor mounted on the bearing B
(only for dual planes balancing)
Note: The bearing marking A and B has only the symbolic sense. It has no relation to the
balancing planes 1,2 and to the balancing computational procedure. You can mark any bearing
as A and the second as B.
Remove Trial yes, no
the trial masses can be left on the rotor or removed after the trial run. When the
trial mass is kept on the rotor, then must be included into final mass figuring
(choice available only for dual planes balancing, for single plane are both
results displayed together)
Balancing Masses
add (mount) / remove (drill)