ADASH Ltd.
Adash 4400 – VA4Pro
For further technical and contact information visit www.adash.eu, email: [email protected]
47
user
user defines Y range for all graphs independently of data values
Cursor for time signals -
single
standard simple cursor
periodic
multiplied cursor with several additions of delta time
delta
band cursor with delta time length
Cursor for spectra -
single
standard cursor
harmonic
cursor with several additions of delta
sideband
cursor with one addition delta
delta
cursor with one addition delta
Cursor position
the time or frequency position of cursor in the selected graph, manual entry available
Delta X
the time or frequency interval used for delta cursor computation, manual entry available
Axe X -
lin, log
Axe Y -
lin, log
Axe Z -
time
scale according time of measurements
speed
scale according the speed of machine (tacho must be used)
regular
regular scale
Order Z -
first in front, last in front
the order of measurements on Y axe
Detect Type - RMS, 0-P, P-P Y axe type
Peaks List -
on, off
the 5 highest spectrum lines table
Synch Table
on, off
table of values synchronized with speed and line frequency
SubSynch - value under speed frequency
Synch - value on speed frequency and harmonics
NonSynch - total value decreased of SubSynch and Synch
Elect - value on line frequency and harmonics (setting in Global Settings / Power/Line Frequency)
All values are in displayed spectrum unit and in % of total value.
Bearing Faults - if the bearing type (or parameters) is defined and the tacho was used for speed measurement,
then the fault frequencies is displayed.