ADASH Ltd.
Adash 4400 – VA4Pro
For further technical and contact information visit www.adash.eu, email: [email protected]
28
Trend Length
auto, value
the length of the trend graph (the range of X axe). It is used for
RunUp measurement and for the Graph Properties / View Trend. When the auto is used, then all data in the
trend are displayed.
Spectrum Settings
These settings are the default settings, which are used for graphs.
Detect Type
RMS, 0-P, P-P
the spectrum values on amplitude axe
Axe X
lin, log
this parameter you can set in Graph Properties functions, which are accessible
in every graph.
Axe Y
lin, log
this parameter you can set in Graph Properties functions, which are accessible
in every graph.
Peaks list
on, off
the list of peaks can be displayed in each spectrum graph
Graph Lines continuous, discrete the spectrum can be drawn as line through the tops of line or as
discrete vertical line for each frequency
Date/ Time
Set the actual date and time.
User Notes Settings
You can attach the short text notes to route points. There are three ways how handle with notes.
1. Enter the note manually.
2. Select predefined note from Factory notes set.
3. Select predefined note from User notes. This set is created and edited by user.