122
tacho
amplitude (positive or negative)
external (voltage)
Signal Range:
full, No Auto ranging
Data acquisition:
TRUE RMS, TRUE PEAK, TRUE PEAK-PEAK overall or band values
user defined high, low and band pass filters for band measurement
time waveforms (8 388 608 samples max)
real-time FFT
3D graphs ( waterfall, cascade)
order analysis
Amp phase values on speed frequency
speed measurement
process static DC or 4-20mA values
Envelope demodulation
ACMT procedure for low speed machines bearings
Time waveform samples:
256 – 8 388 608
Waveform (ACMT) length:
max 131 072
sec (36 hours)
Spectrum ranges:
25 – 90 000 Hz
Spectrum lines:
100 – 3 276 800
Spectrum Peaks listing:
yes
Spectrum units:
RMS, 0-P and P-P
Windows:
Rectangular, Hanning, Exponential, Transient
Order analysis parameters:
1/2 - 10th order
Averaging:
1-255
Overlap:
yes
Smax, Gap and Centerline displays for proximity sensors:
yes
Recording:
Sampling frequency:
user defined in range 64Hz - 196 kHz
Record length example: 3 GB for 1 hour record with 64kHz sampling (4ch AC+4ch DC+1ch tacho signal)
(100GB memory enables over 30 hours of full 64kHz recording,
lower sampling frequency enables much longer record))
Balancing:
Planes:
1 or 2
Speed range:
0,5 Hz - 1000 Hz
Balancing Advisor for automatic fault detection:
yes
Balancing Quality factor according ISO1940:
yes
Balancing vector graph for balancing process reporting:
yes
Balancing Report:
yes
Trim function:
yes
Vector split (e.g. to blades positions):
yes
Manual entry:
yes
Intuitive graphic user interface:
yes
Trial mass:
get out or leave in
General:
Processor:
Atom 1.6 GHz
RAM:
1 GB
Display:
LCD colour 174 x 127 mm (8.5” diagonal), 800x600 resolution
Memory (Internal SSD):
160 GB
Interface:
USB
Powering:
Li-Ion long life battery pack (more then 5 hours of measurement)
Operating temperature:
-10 °C - +50 °C, 15°F-120°F
EMC:
CE tested
Dimensions:
280 x 205 x 55 mm
Weight: