5
8
2
The AUXILIARY output is on when Sensor B is nulled.
5
8
3
The AUXILIARY output is on when the system is nulled.
5
8
4
This option is used only for configuring the resolver’s AUXILIARY output
in resolving-centerline systems. The AUXILIARY output must be
connected to the guide’s AUXILIARY input.
Centerline Configuration
5
9
0
When Centerline mode is selected, the system will calculate Input A +
Input B.
5
9
1
When Centerline mode is selected, the system will calculate (Input A +
Input B) / 2.
This is the default setting.
Offset 1
6 0 1 6 3 8 4
This parameter allows Offset 1 to be examined and modified. Offset 1 is
also accessible through the optional Remote Station or Fieldbus
Interface. To reset Offset 1 to its default value, press the EXIT key.
Range: 1 to 32767
The default value is 16384.
Offset 2
6 1 1 6 3 8 4
This parameter allows Offset 2 to be examined and modified. Offset 2 is
also accessible through the optional Remote Station or Fieldbus
Interface. To reset Offset 2 to its default value, press the EXIT key.
Range: 1 to 32767
The default value is 16384.
Manual Polarity
6
2
0
The actuator extends when the In
mode is selected, and retracts when
the Out mode is selected.
6
2
1
The actuator extends when the Out
mode is selected, and retracts when
the In mode is selected.
This is the default setting.
Integrator Mode
6
3
0
The integrator function is off.
This is the default setting.
6
3
1
This mode is used for applications that require complex control of the
system guide point, but without integration or dampening.
[continued on next page]
MICRO 4000
®
NET Controller
34
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание MICRO 4000 NET
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 122: ...Fieldbus Interface 119 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 125: ...Fieldbus Interface 122 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 128: ...Fieldbus Interface 125 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 132: ...Fieldbus Interface 129 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 136: ...Fieldbus Interface 133 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 141: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 142: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 143: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 144: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 145: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 146: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 147: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 148: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 149: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 150: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 151: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 152: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 153: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 154: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...