Maximum Deadband
6 1 0
The
maximum deadband
is a zone around the sensor guide point where
the motor drive is turned off. The higher the Maximum Deadband value
is set, the farther the web edge or line must move away from the guide
point before the motor drive is turned on. This parameter is typically used
to compensate for edge curl and web flutter. The Maximum Deadband
value must be higher than the Minimum Deadband value.
The default
value is 10.
Range: 0 to 100
Auto-Mode Speed Limit
7 8 0
This parameter limits the top speed of the actuator in Automatic mode.
The higher this value is set, the faster the actuator can move.
The
default value is 80.
Range: 0 to 120
Manual-Mode Speed
8 8 0
This parameter determines how fast the actuator will move in Manual
and Servo-Center mode. The higher this value is set, the faster the
actuator will move.
The default value is 80.
Range: 0 to 120
In End-of-Travel Limit
9 6 7
This parameter works only with actuators that have potentiometer
feedback (MT, SF, HL, HF, HT, and UHT). It sets the maximum distance
that the actuator can move In. To increase this distance, set this
parameter to a lower value.
The default value is 67.
Range: 0 to 255
Important:
Refer to page 84 for minimum and maximum values.
Note:
Use parameter 26 to examine the current actuator position value.
Out End-of-Travel Limit
1 0 1 8 9
This parameter works only with actuators that have potentiometer
feedback (MT, SF, HL, HF, HT, and UHT). It sets the maximum distance
that the actuator can move Out. To increase this distance, set this
parameter to a higher value.
The default value is 189.
Range: 0 to 255
Important:
Refer to page 84 for minimum and maximum values.
Note:
Use parameter 26 to examine the current actuator position value.
Servo-Center Position
1 1 1 2 8
This parameter works only with actuators that have potentiometer
feedback (MT, SF, HL, HF, HT, and UHT). It sets the home position for
the actuator when Servo-Center mode is selected. To move the servo-
center position closer to the In limit, set this parameter to a lower value.
To move the servo-center position closer to the Out limit, set this
parameter to a higher value.
The default value is 128.
Range: 0 to 255
Important:
Refer to page 84 for minimum and maximum values.
Note:
Use parameter 26 to examine the current actuator position value.
MICRO 4000
®
NET Controller
19
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание MICRO 4000 NET
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 122: ...Fieldbus Interface 119 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 125: ...Fieldbus Interface 122 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 128: ...Fieldbus Interface 125 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 132: ...Fieldbus Interface 129 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 136: ...Fieldbus Interface 133 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 141: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 142: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 143: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 144: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 145: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 146: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 147: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 148: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 149: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 150: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 151: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 152: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 153: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 154: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...