F2: setting pulse details
Sets the welding current and welding voltage for the mX Kinetic welding procedure and pulse welding. With
mX Kinetic Move, deeper penetration is possible and the heat input into the base material can be finely
adjusted by individually setting the welding current and welding voltage for the mX Kinetic welding period
and the pulse welding period.
F3: switching the heat input display
The output current/output voltage and the heat input are displayed blinking after the welding process has
been completed.
The heat input is displayed in the digital display as follows:
F67: setting the selection of current values (start
welding parameter, end crater parameter)
ON/OFF
OFF
F68: setting current change values (start welding
parameter)
10 to 300%
100%
F69: setting current change values (end crater
parameter)
10 to 300%
100%
F77: assigning the power source ID
1 to 999
1
F82: starting pulse time configuration (for
aluminum)
0 to 2 s
0.3 s
F83: setting the number of pulses during the start
process (for aluminum)
10 to 300%
100%
F84: starting the pulse feed setting (for aluminum)
200 to −99
0
F86: calibrating the kinetic feed system
ON/OFF
OFF
F87/F88: setting the wire feed characteristic
100 to −100
0
50 to −50
0
F90: setting the backburn retraction quantity
10 to −10
0
Tab. 35
Overview of internal functions
No./function name
Adjustable range Starting value
Adjustable range
ON/OFF
Default value
OFF
Storage option
No
Description
ON: The welding current and welding voltage for the mX Kinetic
welding period and the pulse welding period can be set individually.
OFF: The welding current and welding voltage in the mX Kinetic welding
period and the pulse welding period have the same set values.
Adjustable range
ON/OFF
Default value
OFF
Storage option
No
Description
ON: displays the heat input.
OFF: does not display the heat input.
Right digital display
Heat input range
Unit
0J
0 to 999
J
3J
1 to 999
kJ
6J
1 to 999
MJ