7.10 Carrying out the welding process
7.10.1 Starting the welding process
1
Check the set welding parameters to ensure they are correct.
2
Activate the "Welding start" signal.
During welding, the welding current is displayed on the left digital display and the welding voltage is
displayed on the right digital display in real time. This display shows the average value of the last second.
At the end of the welding process, the average value of the welding current and welding voltage in the last
second of the main welding parameter is displayed on each digital display in a blinking mode.
► Press any button when the value blinks on the control panel to change the display to the set value.
► If necessary, change the length of time for which the display flashes using the internal function
"F8: setting the display hold time".
If the welding time is short, an accurate value may not be displayed. The displayed value is calculated by
the device’s software and cannot be used as a control value for the measuring instrument.
7.10.2 Adjusting parameters during the welding process
The welding current and welding voltage can be adjusted in each sequence (start welding parameter, main
welding parameter, end crater filling parameter).
If no operation is performed for 5 seconds, the digital display switches to the present values.
When the LED above the <Synergy mode ON/OFF> button is illuminated, the voltage is automatically set
to the appropriate welding current.
10
Press <Enter>.
11
When <End> is displayed in both digital displays, set
the main switch to <0>.
A
m/min.
sec.
Hz
±
V
%
JOB.No.
1
Press the <Parameter selection> button.
The digital displays switch to the set values.
2
If the LED above the <Toggle welding current/wire feed speed> button
does not illuminate, press this button.
3
Set the welding current using the <Parameter setting> knob.
4
If the LED above the <Toggle voltage> button does not illuminate, press this
button.
5
Set the welding voltage with the <Parameter setting> knob.
6
Press the <Parameter selection> button.
The digital displays switch to the present values.
A
m/min.
V
±