EN
-
84
9 Maintenance and cleaning
iROB
®
501 PRO
9.1 Maintenance and cleaning intervals
The specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be recorded.
Daily
► Check that the device is properly grounded.
► Make sure that there is no abnormal heat generation along the
cables.
► Check the cables are securely connected.
► Check that there are no problems with the insulation between the
cables and the component.
► Check that the cables are not damaged.
► Check that none of the welding power source plastic covers are
damaged.
► Check that there are no metallic noises, abnormal vibrations, or burnt
odors in the device.
► Check that the fan rotates smoothly and evenly and that air is coming
out of the vents on the front and rear of the device.
► Check that the buttons on the control panel function normally.
► Make sure that there are no large fluctuations in the primary power
supply.
Push Feeder KINETIC:
► Check the guides for dirt and clean if necessary. Replace worn or
deformed components.
► Check the wire feed rolls for dirt and clean if necessary.
► Check the bottom of the device for cleanliness and clean if necessary.
Pull Feeder KINETIC:
► Check the wire feed rolls for dirt and clean if necessary.
► Check the insulation on the conveyor roller. Replace if damaged.
► Check components that guide wire for cleanliness and clean if
necessary.
Wire Buffer KINETIC:
► Check for damage and replace worn components.
Weekly
Pull Feeder KINETIC:
► Use reduced compressed air to clean the Pull Feeder KINETIC and
the wire guide.
Quarterly
Push Feeder KINETIC:
► Check the encoder cable for damage. Check that the plug is secure.
Clean if necessary. Replace worn components.
► Check the motor cable for damage. Replace worn components.
► Replace worn components.
Pull Feeder KINETIC:
► Check the pressure roll for ease of movement and clean the quick-
release axles and rolls if required. Replace components if they do not
move smoothly.
► Replace the worn wire guide in the wire conduit. Check all
connections are secure and tighten if necessary. Replace worn
components.
Wire Buffer KINETIC:
► Check the encoder plug for a tight fit and fasten the plug if necessary.
► Check the encoder cable for damage, clean, and replace worn
components.
► Check the encoder cable is securely connected and tighten the
connector if necessary.
► Check the motor cable for damage and replace worn components.