![Abicor Binzel iROB 501 PRO Скачать руководство пользователя страница 114](http://html2.mh-extra.com/html/abicor-binzel/irob-501-pro/irob-501-pro_original-operating-instructions_5036310114.webp)
EN
-
114
13 IFR-800 fieldbus connection tool
iROB
®
501 PRO
6
–
Arc characteristic
Specifies the arc characteristic.
7
–
En ratio
Specifies the En ratio.
8
0
Voltage setting for
synergetic mode
1: SYNERGETIC mode
0: individual mode
8
1
Setting for
wire feed speed
1: setting for wire feed
speed
0: welding current setting
8
2
Setting for wire feed speed 1: valid
0: invalid
9–10
–
Welding current
Specifies the welding current.
11–12
–
Wire feed speed
Specifies the wire feed speed.
13–14
–
Welding voltage
Specifies the welding voltage.
15
–
Fine adjustment of welding
voltage for synergetic mode
Specifies the fine adjustment of welding voltage for
synergetic mode.
16–17
–
Move frequency
Specifies the move frequency.
18/21/
24/27
–
Function
(port 1 to 4) no.
Sets the function number.
0–6
Function (port 1 to 4) display
change
Changes the function value display.
19–20
/22–23
/25–26
/28–29
–
Function (port 1 to 4) setting
value
Setting for function values.
Tab. 55
Simplified table for output data
Offset
Bit
Function
Description